FMAC RAIL 1- stage filter for 3-phase systems, DIN rail mounting

Series: FMAC RAIL

Free Sample Request

1- stage filter for 3-phase systems, DIN rail mounting

4 Variants


Description FMAC RAIL

Description

  • 3 phase line filter with standard attenuation
日期 子类别 语言 标题 下载
24/11/2017
白皮书 英语 (English) White Paper Leakage currents

Rated Current

Rated Current


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

3 - 20 A @ Ta 40 °C

Rated voltage

Rated Current


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

480 VAC, 50/60 Hz

Approval for

Approval for


Approvals indicate the conformity of the products with the national testing institution requirements by listing of the relevant approval logos.

The link leads you to the search mask where you can query for certificates of the selected products.
Approvals

Detailed information about Approvals will be documented in the general product informations.
Details about Approvals

3 - 20 A @ Ta 40 °C / 480 VAC; 50/60 Hz

Overload Current

1.5 x Ir for 1 minute, per hour

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (440 V / 50 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.

Dielectric Strength

480 VAC:
2.25 kVDC between L-L
3 kVDC between L-PE
Test voltage (2 sec)

Number of Filter Stages

Filter Stages


Quality of a filter

1-stage

Weight

 0.4 kg

Material: Housing

Metal 

Sealing Compound

UL 94V-0 

Mounting

DIN rail mounting 

Terminal

Terminal


AMP = standardized connector systems and contacts
Abbreviation for "Zero Insertion Force". The so-called ZIF connector takes the flexprint cable without effort, mostly with locking. The advantage of this connector is the gentle treatment of the pin

Bolts and nuts M4, Quick connect terminal for PE 

Operating Temperature

-25 °C to 100 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/100/21 acc. to IEC 60068-1

Degree of Protection

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

IP20 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information

Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 200'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: FMAC

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40030735
Approval marks cURus UL UL File Number: E72928


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

预览
 

图片 选择产品图片可显示该类型的特定型号

型号
 

型号 对应于产品系列并包括各种不同型号。总结了有关类型的说明性数据,例如在数据表中

订单编号
 

订单编号 用于下达订单的唯一料号

配置键
 

配置键 产品的配置键由复合键值构成,这些值说明不同种类的属性特性。

注释
 
可能的焊盘图案,采用SMD安装
 

可能的焊盘图案,采用SMD安装 CAD 模型的简略说明

IGS
 

IGS 也称为 IGES(初始图形交换规范)。用于 3D CAD 数据的公共程序独立交换格式。

Step
 

Step 也称为 STEP(产品模型数据交换标准)。适用于按照 ISO 标准进行标准化的 3D CAD 数据的公共程序独立交换格式。

Parasolid
 

Parasolid 参数化实体建模内核是一种 3D CAD 系统。它由 Unigraphics Solutions (UGS)(现为 Siemens PLM Software)内的单独业务部门开发。

DXF
 

DXF (图形交换格式)是由 Autodesk 为 CAD 数据交换而指定的文件格式,专门为 2D-CAD 程序 AutoCAD 而开发。DXF 文件按照 ASCII 标准将 CAD 模型描述为纯文本。

FMAC RAIL
FMAC-3RYB-1010 FMAC-3RYB-2010 FMAC-3RYB-0310 FMAC-3RYB-0610
FMAC-3RYB-xxxx

Dimension [mm]

1) Line
2) Load
3) Tightening torque 0.6-0.8 Nm, Screw 4mm²
4) Quick connect terminal 6.3x0.8mm

Diagrams

1) Line
2) Load

Technical data to the filter components

Rated Current [A] Rated Voltage [VAC] L [mH] C1 [nF] C2 [nF] Filtertyp
           
10 - 1 100 4.7 Standard Version
20 - 0.22 100 22 Standard Version
3 - 3 100 4.7 Standard Version
6 - 2 100 4.7 Standard Version

Attenuation Loss

3 A

6 A

10 A

20 A


Short Table of Variants FMAC RAIL Open complete table FMAC RAIL


Rated Current [A] Tripped Power Dissipation [W] Leakage Current [mA] @ 440V, 60Hz 1) Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:
Contact-Form

Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check
Stock Check Distributor

...
 
10 2.6 0.02 FMAC-3RYB-1010  A  ...
20 4.9 0.08 FMAC-3RYB-2010  A  ...
3 1.1 0.02 FMAC-3RYB-0310 ...
6 2.3 0.02 FMAC-3RYB-0610 ...

Most Popular.

1) Nominal leakage current acc. to IEC60950 - 5.2.5. under normal operating conditions. Note: worst case leakage current acc. to IEC60950 - Annex G4 (situation with two interrupted lines) can be much higher.

2) Maximum conductor cross section (wire gauge) to be used; a comparative table for AWG and mm² values can be found in the general product information␍https://www.schurter.com/en/FAQ#10


ticomel.schurter.com