• 新闻
  • 联系SCHURTER
  • safe&easy
  • DE EN 中文
结果 out of 阅读更多 产品 查看所有结果

分享

分享此页面

您可以通过发送所选页面的URL与他人共享此页面。

Email LinkedIn
Bowdencables incl. accessory Type A (Snap-in mounting) Phase-out␍Last Order date: 30.06.2017␍Last delivery date: 30.09.2017
Type A (Snap-in mounting)
Phase-out␍Last Order date: 30.06.2017␍Last delivery date: 30.09.2017
Bowdencables incl. accessory Type B (Screw-on mounting) Phase-OutLast order date: 31.03.2015
Type B (Screw-on mounting)
Phase-OutLast order date: 31.03.2015
Bowdencables incl. accessory Type A (Snap-in mounting) Phase-out␍Last Order date: 30.06.2017␍Last delivery date: 30.09.2017
Bowdencables incl. accessory Type B (Screw-on mounting) Phase-OutLast order date: 31.03.2015

Series: Bowdencables incl. accessory

Phase_Out_Logo

Bowden Cable for Power Entry Modules

Description Bowdencables incl. accessory

Description

  • Component: Snap-in mounting from front side:
  • Approved together with power entry module

Characteristics

  • Designed for universal industrial applications

Remote Actuator Technology The remote actuator cable assembly consists of a wire cable inside of a plastic insulated spiral wire casing. Identifying a proper outing of the cable assembly is important. Deviations from line to line placement will require bends in the cable with resulting losses in the overall assembly. These inefficiencies show up as friction losses and lost motion. Frictional losses are increases in actuation force due to losses in the assembly. Lost motion is an undesirable difference between the input end of the assembly and the output end. The principle element of lost motion is backlash and deflection. Backlash is caused by the wire cable moving inside the casing with the change in direction of motion. It is the function of clearance between the wire cable and casing, plus the number of degrees of bend in the cable assembly. Deflection of the cable assembly, while usually low, can be minimized by anchoring the casing. This is especially true in those applications of cable assemblies with long lengths and/or large degrees of bend in the system. All of these losses and resulting inefficiencies can be reduced by the equipment designer through minimizing the total degress of bend in the assembly. Because of the number of variables effecting proper operation of any remotely actuated switch assembly, it is important that the ordering instructions be used to determine proper cable length and to provide samples for customer approval. Consult figure for minimum information required to describe cable assembly application. How to specify length of a Bowden cable: R Mounting parallel to direction of actuation␉S Mounting 90° to direction of actuation B1 Actuating part␉␉␉␉B1 Actuating part B2 Power entry module␉␉␉B2 Power entry module ____________________________␉␉_____________________________ R a / b / ␉␉␉c / S a/ b/ c/ Ordering example: The following 3 positions are necessary to place an order: 1. Order No. socket KD14.4199.151 2. Order No. fuse drawer 4303.2024.03 3. Bowden cable (type of mounting /dimensions in mm) *R a/200 b/180 c/40 * The Order No. for a customer specific Bowden cable you’ll get with the acknowledgment. Delivery time for a customer specific Bowden cable sample approx. 2 weeks. Standard Bowden cable sample, Order No. 0886.0101, ex stock

日期 子类别 语言 标题 下载
21/02/2019
产品彩页 英语 (English) Flyer Components and Solutions for Medical Equipment
20/04/2016
PCS 英语 (English) Bowden Cable Typ B2 without button
20/04/2016
PCS 英语 (English) Bowden Cable Typ B1
20/04/2016
PCS 英语 (English) Bowden Cable Typ B2

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

预览
 

图片 选择产品图片可显示该类型的特定型号

型号
 

型号 对应于产品系列并包括各种不同型号。总结了有关类型的说明性数据,例如在数据表中

订单编号
 

订单编号 用于下达订单的唯一料号

配置键
 

配置键 产品的配置键由复合键值构成,这些值说明不同种类的属性特性。

注释
 
可能的焊盘图案,采用SMD安装
 

可能的焊盘图案,采用SMD安装 CAD 模型的简略说明

IGS
 

IGS 也称为 IGES(初始图形交换规范)。用于 3D CAD 数据的公共程序独立交换格式。

Step
 

Step 也称为 STEP(产品模型数据交换标准)。适用于按照 ISO 标准进行标准化的 3D CAD 数据的公共程序独立交换格式。

Parasolid
 

Parasolid 参数化实体建模内核是一种 3D CAD 系统。它由 Unigraphics Solutions (UGS)(现为 Siemens PLM Software)内的单独业务部门开发。

DXF
 

DXF (图形交换格式)是由 Autodesk 为 CAD 数据交换而指定的文件格式,专门为 2D-CAD 程序 AutoCAD 而开发。DXF 文件按照 ASCII 标准将 CAD 模型描述为纯文本。

Bowdencables incl. accessory Bowdencables and accessories
0886.0101

Dimension [mm]

Type A (Snap-in mounting)
Dimension A will be evaluated and defined in trials by SCHURTER based on customer information a, b and c. (See Type R and Type S diagram below.)
Type B (Screw-on mounting)
Dimension A will be evaluated and defined in trials by SCHURTER based on customer information a, b and c. (See Type R and Type S diagram below.)
Panel cutout for snap-in mounting

Panel cut-out for screw version


Assembly Instructions

Drop bowden barrel into seat of switch
Slide clamp around cable
Bowden cable locked into assembly
Type R

Type R


R Mounting parallel to direction of actuation
B1 Actuation part
B2 Power entry module
Dimensions in mm (center of mounting Ø [B1], outer surface to center of mounting Ø [B2] outer surface)
Type S

Type S


S Mounting 90° to direction of actuation
B1 Actuating part
B2 Power entry module
Dimensions in mm (center of mounting Ø [B1], outer surface to center of mounting Ø [B2], outer surface)


ticomel.schurter.com
cns
cns
prod //cdn.schurter.com